Preface
Introduction
Definition
Principle of operation
Terminology
Better Air Flow
Pumping Head
Life Factor
Smaller Fan Motors
Casing
Classification
Thermal Design
Sump
Suction tank/auxiliary tank
Tower Structures
Fills
Sprinkler
Fan/ Fan Blades
Fan Drive Motor
Grills
Drift Eliminators
Installation
Towers
Sprinkler Assembly
Normal Conditions
Water quality Control
Post Erection Checks
Pre-commissioning checks
Maintenance Schedule
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
   
 




   
Go To Home Home Search Sitemap
   
   
Sprinkler Assembly
 
a.Sprinkler Pipes

The sprinkler pipes must be clean to prevent any blockage in holes. When cleaning the sprinkler pipes, loosen the lock nut shown in figure to unscrew and remove the sprinkler pipes. On reassembling, be sure the alignment screws ( round head ) are positioned at the top center.

DMA 2117 , DMB 2117 and DMB 6616 upto DMD 1680 have type A and b sprinkler pipes which these are installed as A against A and B against B.

(a) Models : DMA 2116, 2117, 4116, DMB 2116, 2117, 4116 have two way              sprinkler pipes.
(b) Models : DMA 6616 8416, DMB 6616, 8416 have four way sprinkler
             pipes.
(c) Models : DMA 1260, DMB 1260 and DMC 1260 have four way sprinkler              pipes.
(d) Models : DMC 1680 and DMD 1680 have six way sprinkler pipes.
(e) Models : DMA 1616, DMB 1616 and DME 1680 have eight ways sprinkler              pipes.

b. Sprinkler hand

Scale or sludge attached to the narrow space shown as A and B in Figure impedes revolution. If the sprinkler rotation slows down or even stops despite normal water flow the sprinkler pipes or, at the beginning of the season, if the head does not rotate even though the water is flowing at the same rate as last season, dismantle the rotary head for cleaning and checking. For dismantling the small model plastic sprinkler head, refer to figure and proceed as follows:

For dismantling and reassembling the aluminum sprinkler head for the large towers, refer figure and proceed as follows :

Remove the cap and take the nut off. Pull the rotary part off from the fixed section. This permits checking, clearing and if necessary, replacement of section A and B. To replace the lower bearing or oil seal unscrew set screw and remove from which allows replacement of parts. When reassembling, do not wet the bearing potion with water and apply ample anti-corrosion lubricant Water proof, Lithium soap- radical grease, on bearings and oil seal position. Also, pay particular attention when passing the oil seal over the center pole to not to damage the lips of the oil seal. Since the oil seal is effective for a limited period, it is desirable to dismantle and replace it every two or three years.

c. Details of Oilseal and Bearing in sprinkler assembly


S.No. Sprinkler sizes Oil Seal No Bearing No. CirclipSizes Screws
S.S. Bolts
      Top  Bottom    
1. 1 1/4"x2 way 12-22-7 1438 HH 6001 Z 9 mm -
2. 1 1/4" x 4 way 12-22-7 1438 HH 6001 Z 9 mm -
3. 2"      x 2 way 16-28-7 6003 2Z 6003 2Z 16 mm -
4. 2"      x 4 way 16-28-7 6003 2Z 6003 2Z 16 mm -
5. 2" 1/2 x 4 way 16-28-7 16-28-7 6003 2Z 16 mm -
6. 4"      x 6 way 25-38-7 6004 6005   Z 19 mm 8 m x
20 mm
7. 4"      x 8 way 25-38-7 6004 6005   Z 19 mm 8 m x 20 mm


d. Fan motors bearing details of different make as per the HP rating


HP / MAKE 1
HP
1.5 HP 2
HP
3
HP
5
HP
7.5 HP 10 HP 15
HP
20
HP
HINDUSTAN SHAFT 19mm DE 6205
NDE 6205
6206
6205
6205
6206
6206
6206
6308
6308
6308
6309
6308
6308
6309
6209
6209
6310
6310
6310
N.A.
N.A.
N.A.
N.A.
N.A.
N.A.
SHAFT 28mm DE 6206
NDE 6205
SPARTAN DE 6205
NDE 6205
6206
6206
6206
6206
6308
6208
6309
6308
6309
6308
6311
6311
N.A.
N.A.
N.A.
N.A.
KEC. 
(MOTORIZED)
(GEAR UNIT)
N.A.
N.A. N.A. N.A. N.A. N.A. N.A. GEARBOX GEARBOX
6313 NJ 308
6306/6306
MOTOR
6313 NJ 308
6306/6306
MOTOR
6309/6209 6309/6209
   
   
   
   
   


 